DC Wire Gauge & Voltage Drop Calculator
In short, Undersized wires overheat, waste solar energy, and trip sensitive inverters. Calculate the exact AWG conductor size and fuse protection needed for your DC circuit.
1. Electrical Circuit Parameters
2. Wire Length & Distance
Why 3% Voltage Drop Matters on 12V Systems
On a 120V household wall outlet, a 3-volt drop is just 2.5% โ you would never notice. But on a 12V DC system, a 1.5-volt drop represents 12.5% of your total voltage! A 12V compressor fridge or inverter will detect that voltage dip under load and instantly trip on low-voltage disconnect (LVD), thinking the battery is completely dead when it actually isn't.
NEC 310.15 12V DC Conductor Sizing Reference (3% Max Drop)
| Current (Amps) | 5 ft Cable Run | 10 ft Cable Run | 15 ft Cable Run | 20 ft Cable Run | Max Fuse Rating |
|---|---|---|---|---|---|
| 10 Amps | 16 AWG | 14 AWG | 12 AWG | 10 AWG | 15A Fuse |
| 20 Amps | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 25A Fuse |
| 50 Amps | 8 AWG | 6 AWG | 4 AWG | 2 AWG | 60A Fuse |
| 100 Amps | 4 AWG | 2 AWG | 1/0 AWG | 2/0 AWG | 125A Fuse |
Frequently Asked Questions
How accurate are these engineering numbers?
All figures are derived directly from published empirical engineering standards including NEC 310.15, NREL photovoltaic datasets, and manufacturer polymer technical datasheets.
Are calculations processed on a remote server?
No. Every tool runs 100% locally in your client web browser with zero server transmission, guaranteeing complete data privacy.